Smart alerts for solar installations
Smart alerts complement native inverter alerts by adding additional logic to detect issues that may not trigger a direct inverter error. They are rule-based checks executed daily to analyze installation behavior and detect abnormal situations.
Difference between inverter alerts and smart alerts
-
More data sources
Smart alerts are not limited to inverter status alone. They can combine production data, external data sources (such as weather information), and installation context. They apply across all inverter brands. -
Maintenance-oriented logic
Smart alerts automate key operational checks, allowing energy retailers to quickly identify installations that are not producing as expected and take action at scale.
Available smart alerts
Installation without production alert
Triggers when a solar installation has not reported any production today.
Alert logic:
- The alert is generated when no solar power reading greater than zero has been received today.
- It triggers in both cases: when all the readings received are zero, and when no readings are received at all. An installation that stops sending data is not producing either.
- A single reading greater than zero is enough for the installation to count as producing, and no alert is generated.
Performance loss alert
Triggers when a solar installation is performing at less than 70% of its nominal capacity, based on weather forecast data.
Alert logic:
- Weather data is retrieved every 2 hours, considering the postal code of the residence.
- Actual energy production is compared with estimated production calculated by the system’s data platform.
- If a significant discrepancy is detected, an alert is generated, indicating that the solar panels may be dirty or that shading or obstructions could be affecting performance.